LIST

Atomic Absorption Spectrometer

YK-PAS-3268AA

Product Category: Atomic Absorption Spectrometer

PAS-3268AA atomic absorption spectrophotometer, according to the effect of the ground state of the substance, sensitive and reliable determination of trace or trace elements

image.png

Products Detail Technical Parameter Feature And Application Fields Of Use Download

Excellent fully reflection optical system ensures that the instrument has excellent signal to noise ratio

The atomic absorption spectrometer adopts the unique design of full reflection full band chromatic optical system and full band energy automatic linear balance to ensure the unity and optimal optical position of the sample channel and reference channel at different wavelengths. Keep the beam imaging and SNR at an optimal level to  ensure the accuracy and reliability of the measurement results. All optical components use special processing process is the whole optical system has good reflection efficiency in the deep ultraviolet zone, so that the instrument has a unique excellent signal-to-noise ratio in the full wavelength range.

image.png


Fully safe intelligent gas control module

Adopt modular concept, using integrated air island design and independent microcontroller control. Intelligent 32 grade acetylene gas linear flow regulation and multistage auxiliary air regulation control module; and has intelligent gas abnormal alarm and disconnection function. The safety tank design under the acetylene-air module increases the safety of the flame. Abnormal pressure monitor: the air pressure monitor can detect the change of air pressure at any time during the air-acetylene flame analysis. Once abnormal occurs, it will automatically cut off the acetylene gas and turn out safely. Safety measures of graphite furnace: cooling water flow of graphite furnace, protective gas pressure, furnace body temperature, automatic protection and alarm of graphite pipe installation.




Excellent full-band deuterium lamp background correction technique and high-performance self-priming

The instrument has two background buckle modes of deuterium lamp and self-priming effect. The special automatic optical balance technology broadens the wavelength application range of deuterium lamp background correction. When the background absorbs 1A, the full wavelength light energy automatic balance and photoelectric signal automatic gain double balance technology can obtain more than 40 times, self-priming effect buckle background 80 times of excellent performance!

image.png



MS Window Simple, professional, automatic and fully operated WinAAS workstation software

Rich application experience and professional development technology make the WinAAS operating system not only show excellent professional ability, but also show the humanized and practical characteristics of rich information but clear and understandable, complete functions but easy to use. No professional training that makes you an immediate expert in atomic absorption analysis. From the standard and sample setting, instrument conditions, sample measurement to the output, have experts for your real-time guidance, data output and save conform to the GLP standard, at the same time in the achievement of data, graphics sharing provide text, tables, graphic preservation and curve data export, provide a variety of information support for experimental researchers. If you are the tester, the function you want in the test can be reflected in the WinAAS software.

QA / QC function: Each test with Abs. SD, RSD, while providing the calculated concentration of SD, RSD, test standard sample working curve is automatically check the curve correlation coefficient to ensure the accuracy of the test.

  •  Full information measurement: The results of different data processing methods (average, peak height, peak area and statistical results) are saved for users to study the results. Workstation software can meet the different needs of various users, save and output a variety of data and graphics data, support data processing.

  •  Six correction equations: Six linear and nonlinear concentration calibration methods are provided to ensure the accuracy and stability of the analysis results.

  •   Work software has a rich expert system information database

  •   One key to quickly complete the wavelength, spectral bandwidth, lamp current, negative high voltage, energy balance and other Settings.

  •  The three atomized heating methods of graphite furnace system (general heating, light-controlled high power heating and spatial and temporal high power heating) increase the selectivity and practicability of the atomized temperature conditions.

  •  Unique strong antigenarizer (including graphite furnace and flame) light radiation interference ability;

  •   Appearance design of excellent instruments;

  • Advanced functional module design and manufacturing process design make the instrument have good reliability.