Email

inquiry@yukelab.com

Mob/whatsapp

0086 166 0175 7347

Laser Particle Size Analyzer
LIST

Automatic dry and wet laser particle size

YK6100-D

Product Category: Dry and wet laser particle size

YK6100-D Automatic Dry and Wet Laser Particle Size adopts the most advanced international Mie scattering principle and converging light Fourier transform optical path.


Products Detail Technical Parameter Feature And Application Download

1. Product introduction

YK6100-D High-density probes and full-scale seamless connection test methods ensure the accuracy and repeatability of test results. The unique wet circulation dispersion system ensures that there is no particle deposition during the test process, and no waste liquid accumulation after the test is drained, which ensures the accuracy of the second test and makes the test results more real and reliable; dry dispersion adopts linear spraying Dispersion method, the sample flies vertically backward after being dispersed by high-pressure gas, which avoids the secondary clustering of the particles to be tested, and adopts a non-residue design in the pipeline to ensure the accuracy of testing different samples. The superior optical path automatic calibration system, dry and wet one-key switching system, dry computer remote control feeding system and other elaborate designs highlight the unique advantages of YK6100-D.


2. Product parameter

Specifications

YK6100-D

Executive standard

ISO 13320:2009;GBT 19077-2016

Test Range

Dry method0.01μm -1250μm

Dry method0.1μm-125μm

Number of detector channels

wet method 127

wet method 117

Accuracy error

Dry method: <1%, wet method: <1% (D50 value of national standard sample)

Repeatability error

Dry method: <1%, wet method: <0.5% (D50 value of national standard sample)

Air bubble free

It has a bubble-free design, and the data is more accurate without bubble interference

Misoperation Protection

The instrument has a self-protection function for misoperation, and the instrument does not respond to misoperation

Laser parameters

Double beam, imported fiber output high power semiconductor laserλ= 650nm, p>10mW

Laser intelligent management system

Monitor the working status of the instrument in real time. Once it receives a work command, the intelligent management system will instantly light up the laser. The high-performance laser will reach a stable working status within 3 seconds.

Laser service life

>30000H

Lens

Imported Canon lens

Intelligent operation mode

Both dry and wet tests realize software one-button automatic operation

Wet and dry switching

Software one-button automatic switching without manual operation

Shading detection

The instrument has a unique real-time detection function of shading to ensure more accurate sample addition

Calibration

Automatic calibration system

Optical path alignment

Optical path automatic centering

built-in scatter method

 

 

 

 

Ultrasound

Frequency: f=40KHz, power: p=80W, time: adjustable at will; with ultrasonic anti-dry

To stir

Circulation stirring integrated design, speed: 100-33950rpm speed adjustable

Cycle

Cycle rated flow: 0-10L/min adjustable Rated power: 25W

Sample cell

Self-designed boiling sample pool, better dispersion effect, capacity: 190-600mL can be tested normally

Microsampling

The instrument can be equipped with a micro-automatic testing device, and 10 ml can be used for cyclic testing (optional)

Dry dispersion

 

 

 

Decentralized way

high pressure air dispersion

Feeding method

Mechanical stepless speed regulation vibration feeding, software control

Oil-free silent air compressor

With dust filtering function to ensure test accuracy

Dryer

The freeze dryer can filter the moisture in the air to ensure the dispersion effect

test speed

<1min/time (excluding sample dispersion time)

 

Software function

Testing report

The test report can export Word, Excel, picture (Bmp) and text (Text) and other documents in various forms, satisfying the need to view test reports and quote test results in scientific research articles on any occasion.

DIY

The user can customize the data to be displayed, calculate the percentage based on the particle size, calculate the particle size based on the percentage, or calculate the particle size based on the percentage.

Statistical methods

Volume distribution and number distribution to meet different statistical methods for particle size distribution in different industries.

Statistical comparison

Statistical comparative analysis can be carried out for multiple test results, and the difference between different batches of samples, samples before and after processing, and test results at different times can be clearly compared, which has strong practical significance for the quality control of industrial raw materials.

Analysis mode

Including free distribution, R-R distribution and logarithmic normal distribution, grading statistical mode according to the purpose, etc., to meet the different requirements of different industries for the particle size statistics of the tested samples.

Display template

Calculate the percentage of the particle size range to meet the characterization methods of particle size testing in different industries. Radius distance, consistency, interval accumulation, etc.

Intelligent operation mode

Truly fully automatic unattended operation, no interference from human factors, you only need to add the sample to be tested according to the prompts, and the repeatability of the test results is better.

Multilingual support

Chinese and English language interfaces are supported, and other language interfaces can also be embedded according to user requirements.


3. Product features

★Advanced optical path design: YK6100-D adopts converging light Fourier transform test technology to ensure the maximum range at the shortest focal length, which effectively improves the resolution of the instrument; the unique high-density detection unit enables YK6100-D to have a super strong small particle Test capability, the high-density detection unit uses YK6100-D with super full-scale seamless test capability.

★Double optical path multi-lens technology: YK6100-D high-end version exclusively adopts dual optical path multi-lens technology, which has reached the international advanced level. The main light uses imported fiber optic semiconductor lasers with high stability and long life. Imported fiber semiconductor lasers with long service life.

★Fully sealed fiber semiconductor laser: It adopts a highly stable and long-life fully sealed imported fiber semiconductor laser. The excellent stability makes it have a super test repeatability, and the life is more than 30,000 hours.

★Laser power monitoring and automatic adjustment: exclusive use of constant power laser, real-time detection of laser power and automatic adjustment function, effectively avoiding the problem of laser power attenuation caused by long-term use. At the same time, a constant current, constant voltage and high filter laser power supply is used to effectively prolong the life of the laser, and the normal use can reach more than 30,000 hours.

★Laser intelligent management system: the first to add the laser intelligent management system, the intelligent management system monitors the working status of the instrument in real time, once the intelligent management system receives the work order, the laser will be turned on instantly, and the high-performance laser will reach a stable state within 3 seconds working status. After the sample test is completed, the intelligent management system will automatically turn off the laser, and the laser will basically not attenuate. In theory, there is no need to replace the laser for life.

★One-key switch between dry and wet: the switch between dry and wet will be automatically completed by the instrument, and the whole process will be completed within 10 seconds.

★The main detector moves automatically in the Z direction: after the dry-wet switch, the intervention of optical glass will cause the focal length of the converging light to change. YK6100-D will automatically adjust the main detector according to the difference between dry and wet methods, so that the main detector is always on the focal plane superior.

★Large caliber lens: Large caliber Fourier transform lens can more effectively realize the Fourier transform of optical signal, which is more accurate and effective.

★Anti-dry ultrasonic: YK6100D realizes the water-free protection of the sample pool to avoid damage to the ultrasonic; at the same time, the ultrasonic power is adjustable within the range of 0 to 50 watts.

★Dust-proof and shock-proof design: The overall instrument is sealed, which greatly improves the service life of internal components. The unique suspension structure can effectively avoid the interference of external vibration to the instrument, making the test results more stable and reliable.

★Strong anti-corrosion design (optional): According to the actual needs of customers, it can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oils), and organic solvent resistance (such as acetone, phenol, n-hexane and other organic solvents).

★Imported fiber semiconductor laser: YK6100-D adopts imported high-power fiber output semiconductor laser with high stability and long life. The excellent monochromaticity and stability make YK6100-D have super test repeatability.

★Laser intelligent management system: no need to preheat, switch the laser on demand, the laser will automatically turn off after the sample detection is completed, this system can prolong the service life of the laser and protect the laser from external interference

★Automatic calibration of optical path in X and Y directions: the instrument can adjust the optical path by itself due to slight changes in the optical path caused by the replacement of the sample window.

★Unique micro-circulation system: The entire dispersing circulation system has been optimized for design, and the dispersion medium can be circulated for testing when the dispersion medium is greater than 150 ml, which truly achieves the micro-circulation test; all joints adopt a quick-plug and quick-twist design, and all pipes can be replaced in a short time ; The optimized design ensures that there is no waste residue after drainage, which ensures the accuracy of the next test result.

★Ultra-wide measuring range: YK6100-D has a measuring range of 0.1μm~2000μm for dry method and 0.01μm~2000μm for wet method.

★Exhaust-free air bubble design: The brand-new design prevents air bubbles from entering the test sample window during the entire test process, avoiding air bubble interference.

★Sample residue-free design: The instrument pipeline and drainage structure have been optimally designed, and there is no fluid residue in the instrument pipeline and circulating pump to avoid the impact on the next test data; the dry test is also designed without residue.

★Dry computer remote control feeding: During the YK6100-D dry test, the tester can control the feeding speed through the computer remotely, which greatly reduces the labor intensity of the tester.

★Newly upgraded feeding method: the upgraded dispersed samples directly enter the measurement area, which can effectively solve the problem of inaccurate test results caused by the secondary reunion of samples; at present, only our family adopts this method in China, imported instruments This method is also used. Other manufacturers have to pass through a hose after dispersing, which will cause the samples to reunite.

★Sample window quick change device: The newly designed sample window quick change device makes the sample window replacement more convenient and quick.

Software: Complies with the GMP regulations of the Pharmacopoeia, and has functions such as electronic signature, authority setting, data tracking, and data cannot be changed.

For pharmaceutical industry customers, 3Q certification can be provided.


Download

keyword search:Automatic dry and wet laser particle size

WELCOME TO YUKE

Do you want to Send Inquiry ?

Copyright © Shanghai Yuke Industrial Co., Ltd. All Rights Reserved.