Dry Laser Particle Size Analyzer
YK-3003
YK-3003 is a universal dry dispersion laser particle size analyzer, using the scientific structure design and a new generation of dispersion device, the dispersion effect is better than similar instruments.
YK-3003 is a universal dry dispersion laser particle size analyzer, using the scientific structure design and a new generation of dispersion device, the dispersion effect is better than similar instruments.
YK-3003 is a universal dry dispersion laser particle size analyzer, using the scientific structure design and a new generation of dispersion device, the dispersion effect is better than similar instruments. Using MIE scattering theory as the theoretical basis, converging Fourier transform optical path, and with high stability and He-Ne laser high-sensitivity photodetectors ring ensures repeatability and accuracy of test results.
This product use air as the dispersing medium, the use of turbulent dispersion principle, with high-precision feeding apparatus and Patent powder injection pumps, No-Oil silent air source, ensure that the sample is thoroughly dispersed. It is applied to any powder material, particularly good for materials occurs chemical reaction in water, or shape change in the liquid. It have same accuracy and repeatability compared with the wet method.
1) Unique patent technology of optical path and detection system, greatly improve testing resolution.
Converging Fourier transform optical path patent technology overcome lens aperture restriction on the scattering angle, expand testing range in limited space, and add more secondary integrated photodetectors, which can effectively collect scattered light from all angles in the the corresponding test range, make sure the testing accuracy and reliability within the full range.
2)Scientific and automatic dry dispersing system
Turbulence dispersion patented technology and Normal shock shearing effect make particles sufficient dispersion, dispersion core part using wearable ceramics not only improve dispersion system’s working life but ensure more accurate and stable testing result.
3)Intelligent Operation System realize one key test
Just need put in sample, Dust collection, air supply,feeding and others are all automatic. It only only reduces workload, but eliminate errors caused by human factors, further improve testing accuracy and authenticity of the testing results.
4)Software
Unique unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution, ensure accuracy of testing result.
It’s used to deliver dry powders in the Precise sampling after a variable time duration as required.
The injection speed can be set on the computer according to the fluidity of the sample, very simple to use.
YK-3003 Dry laser particle size analyzer used in cement, ceramics, pharmaceuticals, dyes, pigments, fillers, chemical products, catalysts, coal dust, additives, pesticides, explosives, graphite, photographic materials, fuel, metal and non-metal powder, carbonated calcium, kaolin and other powder industry, particularly for materials which occurs chemical reaction, the shape change and the loss in the liquid, such as herbs, magnetic materials and relatively wide distribution and larger particles powders, have more unique applicability and practicality.
Model Name | YK-3003 Auto Dry Laser Particle Size Analyzer | |
Size Range | 0.1μm-300μm | |
Theory | Laser diffraction theory | |
Method | Mie and Fraunhofer scattering | |
Optical path | Converged light Fourier transform optical path | |
Standard | ISO13320-2020,GB/T19077.1-2016,Q/0100JWN001-2013 | |
Channels Number | 40 pcs (log-spaced array) | |
Accuracy error | <1% (Deviation of D50 on national standard sample) | |
Repeatability error | <1% (Deviation of D50 on national standard sample ) | |
Light Source | High Performance Laser (λ= 639 nm, P>2.0MW) Lifetime>5000 hours | |
Dispersion Method | Dry-turbulence dispersion mode | |
Operation Mode | Manual/Automatic SOP | |
Optical Path Calibration System | Automatic optical alignment system | |
Software | Unconstrained free fitting analysis mode | |
Sample Feeding | Automatic sampler (speed adjustment is available in the computer) | |
Dispersing Medium | Compressed air | |
Test Speed | <1min for each time | |
Connection Port | USB | |
Software function | Analysis mode | Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification |
Statistic Method | ||
Statistic Comparison | Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time. | |
User-defined Analysis | Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries. | |
Test Report | Word, Excel,Photo( Bmp), Text etc | |
Automatic test data selection | Automatically selects stable optical concentration test data, reducing human error and improving test repeatability and reliability. | |
Intelligent Operation Mode | Automatically control Air flow speed, dispersion,test and analysis.Better Repeatability after remove human-factor | |
Data analysis | Average, statistics, and comparison of sample test data in different time periods,Create groups for sample testing to facilitate storage and comparison of sample test data. | |
GMP | Optional | |
Request computer configuration | Windows XP/Windows 7/ Win 10- 64 bits,Core i3/better 2G, Hard disk 160G, Disk D | |
Volume | L765*W450*H325mm Dispersion unit: L260*W285*H135mm | |
Net Weight | 26Kg+7Kg | |
l Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
l Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
l MIE scattering principle application patent No.- ZL 2013 2 0812021.4.
l Dry particle size analyzer full sealed sample cuvette application is protected by patent No.- ZL.2011 2 0267646.8.
l Powder dispersion pump design application is protected by patent No.-ZL 2007 2 0018648.7
Principle:

keyword search:Dry Laser Particle Size Analyzer