1. Product introduction
YK-DT180 Automatic Dynamic Image Granularity Analyzer is also the first particle testing equipment that uses the self-cleaning function of the sample window, which prolongs the service life of the sample window and greatly reduces the frequency of replacement and cleaning.
2. Product parameter
Model | YK-DT180 |
Executive standard | ISO/DIS-13322-2 |
Test Range | 1μm -3000μm |
Repeatability error | <1% (standard sample D50 deviation) |
Light path | Self-designed telecentric optical path system |
Field lens | With anti-distortion field lens to reduce edge distortion and increase depth of field |
Optical lighting | Industrial High Brightness LED Spot Illuminators |
Air bubble free | It has a bubble-free design, and the data is more accurate without bubble interference |
Misoperation protection | The instrument has a self-protection function for misoperation, and the instrument does not respond to misoperation |
Dustproof and shockproof design | The whole machine adopts dustproof and shockproof design |
Camera parameters | 1/3 inch CCD chip, 1920×1080 resolution, frame rate 20, exposure time 9 microseconds |
Decentralized method | Ultrasound | Frequency: f=40KHz, power: p=80W, time: adjustable at will; with ultrasonic anti-dry |
Circulation, stirring | Circulation stirring integrated design, speed: 100-33950rpm speed adjustable |
Circulation flow | Rated flow: 0-10L/min adjustable Rated power: 25W |
Sample cell | Self-designed boiling sample pool, better dispersion effect, capacity: 190-600mL can be tested normally |
Anti-corrosion design (optional) | It can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oils), and organic solvent resistance (all organic solvents such as acetone, phenol, n-hexane, etc.). |
Operating mode | One-button fully automatic software operation mode |
Test speed | <5min/time (excluding sample dispersion time) |
Volume | 980mm*410mm*450mm |
Weight | 30Kg |
Software analysis function |
Task Management Mechanism | Manage according to tasks to ensure that data management is in order. |
Video capture | Collect videos and pictures at any time, and keep the required video data. |
Scale Calibration | Through the scale calibration operation, it can be associated with the actual size, so that the actual size value can be obtained directly on the image. |
Image batch mode | With this mode, it can be processed while collecting, without being limited by memory, and more accurate data can be obtained by processing massive images. |
Particle Automated Toolset | 12 automatic processing tools such as automatic removal of particle adhesion, automatic removal of noise points, automatic removal of incomplete particles, automatic filling of hollow areas of particles, automatic smoothing of particle edges, etc. |
Dynamic processing mode | Select this mode, suitable for dealing with dynamic flowing samples. |
Report output | You can choose the report output style and data type, and you can also customize the report mode according to your needs. |
Intelligent operation mode | Truly fully automatic unattended operation, no interference from human factors, you only need to add the sample to be tested according to the prompts, and the repeatability of the test results is better. |
3. Product features
★Advanced optical path design: YK-DT180 Automatic Dynamic Image Granularity Analyzer adopts a closed telecentric optical path with large depth of field, and cooperates with a constrained flat slot sample window to effectively improve the clarity of particles.
★Particle shape analysis: The analysis of industry-specific particle shape parameters such as sphericity, circularity, roundness, aspect ratio, and sphericity is not available in other particle testing equipment. It is worth mentioning that this product software has added a calculation module for particle circularity (roundness), and the analysis of particle circularity complies with the American oil and gas standard: API_RP58. And it is suitable to apply the industrial specifications of geology, abrasives, oil and gas, etc. of this chart. This calculation module is the only one in China, which is of great significance to the above industries.
★Automatic testing: truly fully automatic testing, all you have to do is put in the sample, no interference data and no manual selection of data.
★Analysis of massive particles, strong data representativeness: Compared with the static sample preparation method of static imager, YK-DT180 Automatic Dynamic Image Granularity Analyzer can measure massive particle data, which is of great significance for the representativeness of particle data.
★Ultrasonic anti-dry function: After painstaking research and development, YK-DT180 Automatic Dynamic Image Granularity Analyzer can realize ultrasonic anti-dry function, avoiding damage to the ultrasonic in the absence of water.
★Dust-proof and shock-proof design: The overall instrument is sealed, which greatly improves the service life of internal components. The unique anti-shock structure can effectively avoid the interference of external vibration to the instrument, making the test results more stable and reliable.
★Unique micro-circulation system: The entire dispersing circulation system has been optimally designed, and the dispersion medium can be circulated for testing when the dispersion medium is larger than 120 ml, which truly achieves the micro-circulation test; the optimized design ensures that there is no waste residue after drainage, ensuring the accuracy of the next test result accuracy. (trace test is optional)
★Exhaust-free air bubble design: The brand-new design prevents air bubbles from entering the test sample window during the entire test, avoiding air bubble interference.
★Sample residue-free design: The instrument pipeline and drainage structure have been optimized, and there is no fluid residue in the instrument pipeline and circulating pump, so as to avoid the impact on the next test data.
★Sample window quick change device: The newly designed sample window quick change device makes the sample window replacement more convenient and quick.
Download
keyword search:Automatic dynamic image granularity analyzer