Email

inquiry@yukelab.com

Mob/whatsapp

0086 166 0175 7347

Laser Particle Size Analyzer
LIST

Micron spray laser granulometry

YK-PW180-B

Product Category: Spray laser particle sizer

YK-PW180-B Micron Spray Laser Granulometry is an upgraded product of PS180 spray particle size analyzer. 

Products Detail Technical Parameter Feature And Application Download

1. Product introduction

YK-PW180-B adopts split design and has a wider scope of application. The performance is more stable, the measurement range is larger, and it is suitable for various complex test environments. At the same time, YK-PW180-B is dust-proof.


2. Product parameter

Specifications

YK-PW180-B

Executive standard

ISO 13320-1:1999; GB/T19077.1-2008

Test Range

1μm-800μm

Number of detector channels

66

Accuracy error

<3% (D50 value of national standard sample)

Repeatability error

<3% (D50 value of national standard sample)

Injection method

open sampling

Instrument structure

Split type or one-piece type optional

Split guide rail (optional)

Separate instrument, the test area can be equipped with guide rails within 3 meters

Laser parameters

Imported fiber optic output high power laserλ= 650nm, power 1-40mw adjustable

Key parameter

measurement area

 

Split type: the instrument can be tested normally within the range of 0.1 to 10 meters

Integrated: instrument 100mm to 340mm

lens

Canon High Performance Lenses

lens protection

air curtain protection

Injection method

Spray (including mist and solid powder)

automatic centering

The instrument automatically adjusts the optical path, and the computer software automatically completes it with one key.

Operating mode

computer operation

Test speed

<1min/time

Weight

25Kg

 

Software function

Testing report

The test report can export Word, Excel, picture (Bmp) and text (Text) and other documents in various forms, satisfying the need to view test reports and quote test results in scientific research articles on any occasion

DIY

User-defined data to be displayed, find the percentage according to the particle size, find the particle size according to the percentage or

Statistical methods

Volume distribution and number distribution to meet different statistical methods for particle size distribution in different industries

Statistical comparison

Statistical comparative analysis can be carried out for multiple test results, and the difference between different batches of samples, samples before and after processing, and test results at different times can be clearly compared, which has strong practical significance for the quality control of industrial raw materials

Analysis mode

Including free distribution, R-R distribution and logarithmic normal distribution, grading statistical mode according to the purpose, etc., to meet the different requirements of different industries for the particle size statistics of the tested samples

Display template

Calculate the percentage of the particle size range to meet the characterization methods of particle size testing in different industries. Radius distance, consistency, interval accumulation, etc.

Intelligent operation mode

Truly fully automatic unattended operation, no interference from human factors, you only need to add the sample to be tested according to the prompts, and the repeatability of the test results is better.

Multilingual support

Chinese and English language interfaces are supported, and other language interfaces can also be embedded according to user requirements.


3. Product features

YK-PW180-B Micron Spray Laser Granulometry adopts a split structure, which can test long-distance samples. YK-PW180-B adopts a large platform, which can meet the normal test at a distance of 0.1 meters to 10 meters even if it is used in one piece.

Advanced optical path design:

YK-PW180-B Micron Spray Laser Granulometry adopts the principle of Fraunhofer diffraction and typical parallel optical path design, and is equipped with a high-power semiconductor laser; the unique high-density detection unit makes YK-PW180-B have super small particle testing capabilities , YK-PW180-B seamless test within 1μm ~ 800μm. At the same time, YK-PW180-B has added an automatic optical path adjustment device, which is convenient for operation and prolongs the service life of the instrument.

High power semiconductor laser:

YK-PW180-B Micron Spray Laser Granulometry uses a high-power semiconductor laser, which enhances the resolution of the instrument and makes small particles nowhere to hide.

Optical path automatic calibration:

YK-PW180-B Micron Spray Laser Granulometry  is the first to add the automatic centering function in the spray particle size analyzer. The optical path automatic adjustment system added by YK-PW180-B ensures the stability and accuracy of the instrument measurement. At the same time, the work intensity of the operator is greatly reduced.

Imported lens:

YK-PW180-B adopts Canon of Japan as the main lens, which has small distortion and high imaging. The receiving end adopts a large-diameter long-focus lens with a diameter of 150mm, which makes particle detection more accurate.

Ultra-wide range:

The measuring range of YK-PW180-B has reached 1μm~800μm.

Fill light positioning:

YK-PW180-B Micron Spray Laser Granulometry has uniquely added auxiliary light positioning function. When positioning, two laser beams at the transmitter emit at the same time. After the two points at the receiver match, the receiver can start the automatic adjustment system of the optical path, which greatly simplifies the adjustment difficulty.

Powerful analysis software:

Powerful analysis software can record the particle size distribution of all droplets in all laser beams at any time. Test results can be continuously recorded and statistically analyzed by moving the spray within the laser beam.


Download

keyword search:Micron spray laser granulometry

WELCOME TO YUKE

Do you want to Send Inquiry ?