1. Product introduction
YK-5100-H is a wet-process fully automatic laser particle size analyzer, which adopts the most advanced international Mie scattering principle and convergent light Fourier transform optical path. High-density probes and full-scale seamless connection test methods ensure the accuracy and repeatability of test results.
2. Product parameter
Model | YK-5100-H (high configuration) |
Executive standard | ISO 13320-1:1999; GB/T19077.1-2008 |
Test Range | 0.1μm -600μm |
Number of detector channels | 88 |
Accuracy error | <1% (D50 value of national standard sample) |
Repeatability error | <0.5% (D50 value of national standard sample) |
Air bubble free | It has a bubble-free design, and the data is more accurate without bubble interference |
Misoperation Protection | The instrument has a self-protection function for misoperation, and the instrument does not respond to misoperation |
Laser parameters | Imported fiber output high power semiconductor laserλ= 635nm, p>10mW |
Optical path calibration | Optical path automatic calibration |
Intelligent operation mode | One-button fully automatic software operation mode |
Test speed | <1min/time (excluding sample dispersion time) |
Built-in scatter method | Ultrasound | Frequency: f=40KHz, power: p=80W, time: adjustable at will; with ultrasonic anti-dry |
To stir | Circulation stirring integrated design, speed: 100-33950rpm speed adjustable |
Cycle | Cycle rated flow: 0-10L/min adjustable Rated power: 25W |
Shading detection | The instrument has a unique real-time detection function of shading to ensure more accurate sample addition |
Sample cell | Self-designed boiling sample pool, better dispersion effect, capacity: 190-600mL can be tested normally |
Dustproof and shockproof design | The whole machine adopts dustproof and shockproof design |
Micro injection (optional) | The instrument can be equipped with a micro-automatic testing device, and 10 ml can be used for cyclic testing (optional) |
Anti-corrosion design (optional) | It can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oils), and organic solvent resistance (all organic solvents such as acetone, phenol, n-hexane, etc.). |
Software Function |
Testing report | The test report can export Word, Excel, picture (Bmp) and text (Text) and other documents in various forms, satisfying the need to view test reports and quote test results in scientific research articles on any occasion |
DIY | User-defined data to be displayed, find the percentage according to the particle size, find the particle size according to the percentage or |
Statistical methods | Volume distribution and number distribution to meet different statistical methods for particle size distribution in different industries |
Statistical comparison | Statistical comparative analysis can be carried out for multiple test results, and the difference between different batches of samples, samples before and after processing, and test results at different times can be clearly compared, which has strong practical significance for the quality control of industrial raw materials |
Analysis mode | Including free distribution, R-R distribution and logarithmic normal distribution, grading statistical mode according to the purpose, etc., to meet the different requirements of different industries for the particle size statistics of the tested samples |
Display template | Calculate the percentage of the particle size range to meet the characterization methods of particle size testing in different industries. Radius distance, consistency, interval accumulation, etc. |
Intelligent operation mode | Truly fully automatic unattended operation, no interference from human factors, you only need to add the sample to be tested according to the prompts, and the repeatability of the test results is better. |
Multilingual support | Chinese and English language interfaces are supported, and other language interfaces can also be embedded according to user requirements. |
Volume | 980mm*410mm*450mm |
Weight | 30Kg |
3. Product features
★Advanced optical path design: YK5100-H Intelligent Full-automatic Wet Laser Granulometeradopts converging light Fourier transform test technology to ensure the maximum measurement range at the shortest focal length, which effectively improves the resolution of the instrument; the unique high-density detection unit enables YK5100-H to have a super strong small particle Testing ability, high-density detection units make YK5100-H have super full-scale seamless testing ability.
★Fully sealed fiber semiconductor laser: YK5100-H Intelligent Full-automatic Wet Laser Granulometeradopts a highly stable and long-life fully sealed fiber semiconductor laser. The excellent stability makes YK5100-H have a strong test repeatability (helium-neon laser is optional).
★Automatic testing: truly fully automatic testing, all you have to do is put in the sample, no interference data and no manual selection of data.
★Ultrasonic anti-dry function: After painstaking research and development, YK5100-H Intelligent Full-automatic Wet Laser Granulometercan realize the ultrasonic anti-dry function, avoiding damage to the ultrasonic in the absence of water.
★Adjustable ultrasonic power: In order to meet the dispersion needs of different samples, the ultrasonic power is 0 to 20 milliwatts.
★Dust-proof and shock-proof design: The overall instrument is sealed, which greatly improves the service life of internal components. The unique anti-shock structure can effectively avoid the interference of external vibration to the instrument, making the test results more stable and reliable.
★Strong anti-corrosion design (optional): According to the actual needs of customers, it can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oils), and organic solvent resistance (all organic solvents such as acetone, phenol, n-hexane, etc.).
★Auto-centering: Exclusively adopts the technology of combining mechanical center and optical center, the automatic adjustment and positioning of the optical path is more accurate, reaching the micron level; at the same time, the optical path adjustment speed is faster and the adjustment can be completed in 15 seconds at the fastest. The self-developed automatic centering system consists of stepper motors, precision guide rails, precision controllers and software systems. The minimum step distance is 0.2 microns, ensuring that the laser beam focus always passes through the center point of the detector, improving the accuracy of test results and testing repeatability. An automatic centering system is standard on all Niket laser particle size analyzer models.
★Unique micro-testing system: YK5100-H has specially designed a micro-circulation system for the field of sewage treatment, which can obtain the particle size distribution of particles in filtered water with very small amounts of impurities. The entire dispersion circulation system has been optimized and designed, and the dispersion medium is greater than 8 It can be tested in milliliters, truly achieving trace testing; it has been well applied to the analysis of water quality median particle size in oil production plants, sewage treatment stations and other places.
★Bubble free design: The new design ensures that no bubbles enter the test sample window during the entire test, avoiding bubble interference.
★No residual sample design: The instrument pipeline and drainage structure are optimized, and there is no residual liquid in the instrument pipeline and circulation pump to avoid affecting the next test data.
★Sample window quick-change device: The newly designed sample window quick-change device makes sample window replacement more convenient and faster.
★Dew point measurement: Fogging on the sample window will affect the accuracy of the measurement. Such test results have no practical significance. YK5100-H is equipped with a fog point measurement system. Once fogging occurs, the software will automatically prompt.
Download
keyword search:Intelligent full-automatic wet laser granulometer