Email

inquiry@yukelab.com

Mob/whatsapp

0086 166 0175 7347

Laser Particle Size Analyzer
LIST

0.1-1250 Wet automatic laser particle size instrument

YK-6100-C

Product Category: Wet laser particle size analyzer

YK-6100-C 0.1-1250 Wet Automatic Laser Particle Size Instrumentadopts the most advanced Mie scattering principle and convergent light Fourier transform optical path in the world. High-density probes and full-scale seamless connection test methods ensure the accuracy and repeatability of test results.

Products Detail Technical Parameter Feature And Application Download

1. Product introduction

The YK-6100-C unique wet circulation dispersion system ensures that there is no particle deposition during the particle test, and there is no waste liquid accumulation after the test is drained, which ensures the accuracy of the second test and makes the test results more real and reliable; at the same time, it adopts the design of no residue in the pipeline, The accuracy of testing different samples is guaranteed. The superior optical path automatic calibration system highlights the unique advantages of YK-6100-C.


2. Product parameter

Model

YK-6100-C

Executive standard

ISO 13320-1:1999; GB/T19077.1-2008

Test Range

0.1μm -1250μm

Number of detector channels

97

Accuracy error

<1% (D50 value of national standard sample)

Repeatability error

<0.5% (D50 value of national standard sample)

Air bubble free

It has a bubble-free design, and the data is more accurate without bubble interference

Misoperation Protection

The instrument has a self-protection function for misoperation, and the instrument does not respond to misoperation

Lens

Imported Canon lens

Laser parameters

Imported fiber output high power laserλ= 650nm, p>10mW

Laser intelligent management system

Real-time monitoring of the working status of the instrument, once the intelligent management system receives the work order, the laser will be turned on instantly, and the high-performance laser will reach a stable working status within 3 seconds

Optical path calibration

Optical path realizes automatic calibration

Intelligent operation mode

Software one-button fully automatic operation

Decentralized method

Ultrasound

Frequency: f=40KHz, power: p=100W, time: adjustable at will; with ultrasonic anti-dry

Circulation, stirring

Circulation stirring integrated design, speed: 100-33950rpm speed adjustable

Circulation flow

Rated flow: 0-30L/min adjustable Rated power: 25W

Sample cell

Self-designed boiling sample pool, better dispersion effect, capacity: 190-600mL can be tested normally

Microsampling

The instrument can be equipped with a micro-automatic testing device, and 10 ml can be used for cyclic testing (optional)

Dustproof and shockproof design

The whole machine adopts dustproof and shockproof design

Anti-corrosion design (optional)

It can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oils), and organic solvent resistance (such as acetone, phenol, n-hexane, isopropanol and other organic solvents).

Test speed

<1min/time (excluding sample dispersion time)

Volume

980mm*410mm*450mm

Weight

35Kg

Software Function

Testing report

The test report can export Word, Excel, picture (Bmp) and text (Text) and other documents in various forms, satisfying the need to view test reports and quote test results in scientific research articles on any occasion

DIY

User-defined data to be displayed, find the percentage according to the particle size, find the particle size according to the percentage or

Statistical methods

Volume distribution and number distribution to meet different statistical methods for particle size distribution in different industries

Statistical comparison

Statistical comparative analysis can be carried out for multiple test results, and the difference between different batches of samples, samples before and after processing, and test results at different times can be clearly compared, which has strong practical significance for the quality control of industrial raw materials

Analysis mode

Including free distribution, R-R distribution and logarithmic normal distribution, grading statistical mode according to the purpose, etc., to meet the different requirements of different industries for the particle size statistics of the tested samples

Display template

Calculate the percentage of the particle size range to meet the characterization methods of particle size testing in different industries. Radius distance, consistency, interval accumulation, etc.

Intelligent operation mode

Truly fully automatic unattended operation, no interference from human factors, you only need to add the sample to be tested according to the prompts, and the repeatability of the test results is better.

Multilingual support

Chinese and English language interfaces are supported, and other language interfaces can also be embedded according to user requirements.


3. Product features

Advanced optical path design: YK-6100-C 0.1-1250Wet Automatic Laser Particle Size Instrument adopts converging light Fourier transform test technology to ensure the maximum range at the shortest focal length, which effectively improves the resolution of the instrument; the unique high-density detection unit enables YK-6100-C to have a super strong small particle Test ability, high-density detection units make YK-6100-C 0.1-1250 Wet Automatic Laser Particle Size Instruments have super full-scale seamless test ability, and the high-end version adopts dual optical path design.

Fully sealed fiber semiconductor laser: It adopts a highly stable and long-life fully sealed imported fiber semiconductor laser. The excellent stability makes it have a super test repeatability, and the life is more than 30,000 hours.

Laser power monitoring and automatic adjustment: exclusive use of constant power laser, real-time detection of laser power and automatic adjustment function, effectively avoiding the problem of laser power attenuation caused by long-term use. At the same time, a constant current, constant voltage and high filter laser power supply is used to effectively prolong the life of the laser, and the normal use can reach more than 30,000 hours.

Laser intelligent management system: the first to add the laser intelligent management system, the intelligent management system monitors the working status of the instrument in real time, once the intelligent management system receives the work order, the laser will be turned on instantly, and the high-performance laser will reach a stable state within 3 seconds working status. After the sample test is completed, the intelligent management system will automatically turn off the laser, and the laser will basically not attenuate. In theory, there is no need to replace the laser for life.

Dust-proof and shock-proof design: The overall instrument is sealed, which greatly improves the service life of internal components. The unique suspension structure can effectively avoid the interference of external vibration to the instrument, making the test results more stable and reliable.

Automatic calibration of X and Y directions of optical path: YK-6100-C exclusively adopts the combination technology of mechanical center and optical center, the automatic adjustment and positioning of optical path is more accurate, reaching the micron level; at the same time, the adjustment speed of optical path is faster and the fastest can be adjusted in 15 seconds.

Intelligent fully automatic operation mode: The software realizes one-button operation, automatic water feeding, automatic sampling, automatic testing, automatic cleaning, and the whole testing process realizes one-button automatic operation, which is convenient and quick to use.

Unique micro-circulation system: The entire dispersing circulation system has been optimized for design, and the dispersion medium can be circulated for testing when it is larger than 180 ml, which truly achieves the micro-circulation test; all joints adopt a quick-plug and quick-twist design, and all pipes can be replaced in a short time ; The optimized design ensures that there is no waste residue after drainage, which ensures the accuracy of the next test result.

Ultra-wide range: YK-6100-C 0.1-1250 Wet Automatic Laser Particle Size Instrument has a range of 0. 1μm~1250μm.

Ultrasonic anti-dry heating: YK-6100-C 0.1-1250 Wet Automatic Laser Particle Size Instrument is equipped with 100W high-power ultrasonic and has the function of ultrasonic anti-dry heating.

Misoperation protection: YK-6100-C 0.1-1250 Wet Automatic Laser Particle Size Instrumenthas a self-protection function, and does not respond to some misoperations that will damage the instrument, which greatly reduces the damage caused by human misoperations.

Dew point measurement: The fogging of the sample window will affect the accuracy of the measurement. Such a test result has no practical significance. YK-6100-C 0.1-1250 Wet Automatic Laser Particle Size Instrumentis equipped with a fogging point measurement system. Once fogging occurs, the software will automatically prompt.

Exhaust-free air bubble design: The brand-new design prevents air bubbles from entering the test sample window during the entire test process, avoiding air bubble interference (the air-free air bubble function technology is exclusively owned by us).

Sample residue-free design: The instrument pipeline and drainage structure have been optimally designed, and there is no fluid residue in the instrument pipeline and circulating pump to avoid the impact on the next test data; the dry test is also designed without residue.

Sample window quick-change device: The newly designed sample window quick-change device makes the replacement of the sample window more convenient and fast (the process of disassembling and assembling the sample window can be completed in 20 seconds).