Laser Particle Size Analyzer
LIST

0.1-500 Full automatic wet laser granulometer

YK-T3100-L

Product Category: Wet laser particle size analyzer

YK-T3100-L 0.1-500 Full Automatic Wet Laser Granulometer is a new portable integrated particle size analyzer launched by our company. It has many advantages such as small size, large measuring range and high degree of automation. Although the range is small, it reaches 0.1μm -600μm. 

Products Detail Technical Parameter Feature And Application Download

1. Product introduction

YK-T3100-L 0.1-500 Full Automatic Wet Laser Granulometer is a wet-process automatic laser particle size analyzer, which adopts the most advanced international Mie scattering principle and convergent light Fourier transform optical path. High-density probes and full-scale seamless connection test methods ensure the accuracy and repeatability of test results.


2. Product parameter

Model

YK-T3100-L (standard configuration)

Executive standard

ISO 13320-1:1999; GB/T19077.1-2008

Test Range

0.1μm -500μm

Number of detector channels

65

Accuracy error

<1% (D50 value of national standard sample)

Repeatability error

<0.5% (D50 value of national standard sample)

Air bubble free

It has a bubble-free design, and the data is more accurate without bubble interference

Misoperation Protection

The instrument has a self-protection function for misoperation, and the instrument does not respond to misoperation

Laser parameters

Imported fiber output high power laserλ= 635nm, p>20mW

Optical path calibration

Optical path automatic calibration

Decentralized method

Ultrasound

Frequency: f=40KHz, power: p=100W, time: adjustable at will; with ultrasonic anti-dry

Circulation, stirring

Circulation stirring integrated design, speed: 100-4000rpm speed adjustable

Circulation flow

Rated flow: 0-10L/min adjustable Rated power: 20W

Sample cell

Self-designed boiling sample pool, better dispersion effect, capacity: 190-600mL can be tested normally

Dustproof and shockproof design

The whole machine adopts dustproof and shockproof design

SoftwareFunction

Analysis mode

Including free distribution, R-R distribution and logarithmic normal distribution, grading statistical mode according to the purpose, etc., to meet the different requirements of different industries for the particle size statistics of the tested samples

Statistical methods

Volume distribution and number distribution to meet different statistical methods for particle size distribution in different industries

Statistical comparison

Statistical comparative analysis can be carried out for multiple test results, and the difference between different batches of samples, samples before and after processing, and test results at different times can be clearly compared, which has strong practical significance for the quality control of industrial raw materials

DIY

User-defined data to be displayed, find the percentage according to the particle size, find the particle size according to the percentage or

Display template

Calculate the percentage of the particle size range to meet the characterization methods of particle size testing in different industries. Radius distance, consistency, interval accumulation, etc.

Testing report

The test report can export Word, Excel, picture (Bmp) and text (Text) and other documents in various forms, satisfying the need to view test reports and quote test results in scientific research articles on any occasion

Multilingual support

Chinese and English language interfaces are supported, and other language interfaces can also be embedded according to user requirements.

Intelligent operation mode

Truly fully automatic unattended operation, no interference from human factors, you only need to add the sample to be tested according to the prompts, and the repeatability of the test results is better.

Operating mode

One-button fully automatic software operation mode

Test speed

<1min/time (excluding sample dispersion time)

Volume

750mm*270mm*315mm

Weight

25Kg


3. Product features

Advanced optical path design: YK-T3100-L 0.1-500 Full Automatic Wet Laser Granulometer adopts converging light Fourier transform test technology to ensure the maximum range at the shortest focal length, effectively improving the resolution of the instrument; the unique high-density detection unit enables YK-T3100-L to have super small particle Test ability, high-density detection unit makes YK-T3100-L have super full-scale seamless test ability.

Fully sealed fiber semiconductor laser: YK-T3100-L Adopts highly stable and long-life Japanese Mitsubishi fully sealed fiber semiconductor laser. The excellent stability makes the particle size analyzer have super test repeatability, and the laser power of YK-T3100-L is adjustable. , the maximum laser power has also reached 20mw.

Automatic testing: truly fully automatic testing, all you have to do is put in the sample, no interference data and no manual selection of data.

Ultrasonic anti-dry function: YK-T3100-L 0.1-500 Full Automatic Wet Laser Granulometer can realize ultrasonic anti-dry function, avoiding damage to the ultrasonic in the absence of water.

New SOP self-editing function: In order to meet the test needs of different samples, JH5200-H realizes the SOP self-editing function, edit different test procedures according to different samples, and directly call and use next time after editing and saving once.

Dust-proof and shock-proof design: The overall instrument is sealed, which greatly improves the service life of internal components. The unique anti-shock structure can effectively avoid the interference of external vibration to the instrument, making the test results more stable and reliable.

Optical path adjustment: the computer remotely controls the precision self-locking motor, precision guide rail, precision controller and software system, with a minimum step distance of 1 micron to ensure that the laser beam focus always passes through the center of the detector, improving the accuracy of test results and Test repeatability. The automatic centering system is the standard configuration of all models of Niket laser particle size analyzers.

Bubble free design: The new design ensures that no bubbles enter the test sample window during the entire test, avoiding bubble interference.

Channel steel guide rail: The optical path guide rail is made of thickened channel steel, which makes the optical path system more stable and reliable, while reducing the impact of temperature and humidity on the optical path.

Sample residue-free design: The instrument pipeline and drainage structure have been optimized, and there is no fluid residue in the instrument pipeline and circulating pump, so as to avoid the impact on the next test data.

Sample window quick change device: The newly designed sample window quick change device makes the sample window replacement more convenient and quick.